--- abstract: |-2 Syncope is a common clinical disorder accounting for 3 % for emergency room presentations and 1 % of hospital admissions 1. Moreover it has not always a benign course, with mortality rates up to 33 % at 1 year in patients with a structural cardiac disorders 2, 5. In addition costs for investigation for syncope is substantial and about 25 % of all patients remain undiagnosed 6. Investigation of patients with recurrent unexplained syncope may include electrocardiography and treadmill exercise testing, neurologic testing, tilt table testing, ambulatory Holter monitoring and electrophysiological testing. This review will briefly discuss these current available strategies and focus on the usefulness of a recently introduced tool using an implantable loop recorder (ILR) in the treatment of patients with a recurrent unexplained syncope. altloc: - http://www.ipej.org/0201/cock.htm chapter: ~ commentary: ~ commref: ~ confdates: ~ conference: ~ confloc: ~ contact_email: ~ creators_id: [] creators_name: - family: Cock given: Carel C. honourific: '' lineage: '' date: 2002-01 date_type: published datestamp: 2005-05-02 department: ~ dir: disk0/00/00/43/23 edit_lock_since: ~ edit_lock_until: ~ edit_lock_user: ~ editors_id: [] editors_name: - family: Singh given: Balbir honourific: '' lineage: '' - family: Lokhandwala given: Yash honourific: '' lineage: '' - family: Francis given: Johnson honourific: '' lineage: '' - family: Gupta given: Anup honourific: '' lineage: '' eprint_status: archive eprintid: 4323 fileinfo: /style/images/fileicons/text_html.png;/4323/1/cock.htm full_text_status: public importid: ~ institution: ~ isbn: ~ ispublished: pub issn: ~ item_issues_comment: [] item_issues_count: 0 item_issues_description: [] item_issues_id: [] item_issues_reported_by: [] item_issues_resolved_by: [] item_issues_status: [] item_issues_timestamp: [] item_issues_type: [] keywords: Implantable Loop Recorders lastmod: 2011-03-11 08:56:02 latitude: ~ longitude: ~ metadata_visibility: show note: ~ number: 1 pagerange: 15-19 pubdom: TRUE publication: Indian Pacing and Electrophysiology Journal publisher: Indian Pacing and Electrophysiology Group refereed: TRUE referencetext: |- 1. Heaven DJ, Sutton R Syncope: Crit Care Med. 2000 Oct: 28(10 Suppl):N116-20. 2. Kapoor WN, Karpf M, Wieand S, Peterson JR, Levey GS: A prospective evaluation and follow-up of patients with syncope. N Engl J Med. 1983 Jul 28;309(4):197-204. 3. Day SC, Cook EF, Funkenstein H, et al: Evaluation and outcome of emergency room visits with transient loss of consciousness. Am J Med 1992; 73:15-23. 4. Linzer M, Yang EH, Estes M III, et al: Diagnosing syncope: Part 2; Unexplained syncope. Ann Intern Med 1997; 127:76-86. 5. Linzer M, Yang EH, Estes M III, et al: Diagnosing syncope: Part 1 Value of history, physical examination, and electrocardiography. Ann Intern Med 1997; 126:989-966. 6. Calkins H, Byrne M, El-Atassi R, et al: The economic burden of unrecognized vasodepressor syncope. Am J Med 1993; 95:473-479. 7. Brugada J, Brugada R, Brugada P: Right bundle branch block and ST segment elevation in leads V1 through V3: a marker for sudden death in patients without demonstrable structural heart disease. Circulation. 1998;97:457–460. 8. Camm AJ, Janse MJ, Roden DM, Rosen MR, Cinca J, Cobbe SM: Congenital and acquired long QT syndrome.Eur Heart J. 2000 Aug;21(15):1232-7. 9. Domenico Corrado, Cristina Basso, Gaetano Thiene: Arrhythmogenic right ventricular cardiomyopathy: diagnosis, prognosis, and treatment. Heart. 2000 May;83(5):588-95. 10. Recchia D, Barzilai B: Echocardiography in the evaluation of patients with syncope. J Gen Intern Med 1995; 10:649-655. 11. Benditt DG, Ferguson DW, Grubb BP, Kapoor WN, Kugler J, Lerman BB, Maloney JD, Raviele A, Ross B, Sutton R, Wolk MJ, Wood DL.:Tilt table testing for assessing syncope. American College of Cardiology.J Am Coll Cardiol. 1996 Jul;28(1):263-75. 12. Kosinski D, Grubb BP, Karas BJ, Frederick S.: Exercise-induced neurocardiogenic syncope: clinical data, pathophysiological aspects, and potential role of tilt table testing. Europace. 2000 Jan;2(1):77-82. 13. Parry SW, Kenny RA. :The role of tilt table testing in neurocardiocascular instability in older adults.Eur Heart J. 2001 Mar;22(5):370-2. 14. Kenny RA, Ingram A, Bayliss J, et al: Head-up tilt: A useful test for investigating unexplained syncope. Lancet 1986; 1:1352-1354. 15. D.G. Benditt, D.W. Ferguson, B.P. Grubb, W.N. Kapoor, J. Kugler, B.B. Lerman, J.D. Maloney, A. Raviele, B. Ross, R. Sutton, M.J. Wolk and D.L. Wood: Tilt table testing for assessing syncope: American College of Cardiology. J Am Coll Cardiol 28 (1996), pp. 263¯275. 16. Connolly SJ, Sheldon R, Roberts RS, Gent M.:The North American Vasovagal Pacemaker Study (VPS). A randomized trial of permanent cardiac pacing for the prevention of vasovagal syncope. J Am Coll Cardiol. 1999 Jan;33(1):16-20. 17. Benditt DG. Cardiac pacing for prevention of vasovagal syncope: J Am Coll Cardiol 1999; 33:21-23. 18. DiMarco JP: Value and limitations of electrophysical testing for syncope.Cardiol Clin. 1997 May;15(2):219-32. 19. Krahn AD, Klein GJ, Norris C, Yee R: The etiology of syncope in patients with negative tilt table and electrophysiological testing.Circulation. 1995 Oct 1;92(7):1819-24. 20. Krahn AD, Klein GJ, Yee R. Norris C: Final results from a pilot study with an implantable loop recorder to determine the etiology of syncope in patients with negative noninvasive and invasive testing. Am J Cardiol. 1998 Jul 1;82(1):117-9. 21. Krahn AD, Klein GJ, Yee R, Takle-Newhouse T, Norris C: Use of an extended monitoring strategy in patients with problematic syncope. Reveal Investigators. Circulation. 1999 Jan 26;99(3):406-10. 22. Nierop PR, van Mechelen R, van Elsacker A, Luijten RH, Elhendy A. :Heart rhythm during syncope and presyncope: results of implantable loop recorders.Pacing Clin Electrophysiol. 2000 Oct;23(10 Pt 1):1532-8. 23. Waldo AL, Biblo LA, Carlson MD.:Ventricular arrhythmias in perspective: a current view. Am Heart J. 1992 Apr;123(4 Pt 2):1140-7. 24. Zellerhoff C, Himmrich E, Nebeling D, Przibille O, Nowak B, Liebrich :A. How can we identify the best implantation site for an ECG event recorder? Pacing Clin Electrophysiol. 2000 Oct;23(10 Pt 1):1545-9. 25. Krahn AD, Klein GJ, Yee R, Manda V: The high cost of syncope: cost implications of a new insertable loop recorder in the investigation of recurrent syncope. Am Heart J. 1999 May;137(5):870-7. 26. de Cock CC, Spruijt HJ, van Campen LM, Plu AW, Visser CA.: Electromagnetic interference of an implantable loop recorder by commonly encountered electronic devices. Pacing Clin Electrophysiol. 2000 Oct;23(10 Pt 1):1516-8. 27. Brignole M, Menozzi C, Moya A, Garcia-Civera R: International Study on Syncope of Uncertain Etiology (ISSUE) Investigators. Implantable loop recorder: towards a gold standard for the diagnosis of syncope? Heart. 2001 Jun;85(6):610-2. 28. Kenny RA, Krahn AD: Implantable loop recorder: towards a gold standard for the diagnosis of syncope? Heart. 2001 Jun;85(6):610-2. relation_type: [] relation_uri: [] reportno: ~ rev_number: 8 series: ~ source: ~ status_changed: 2007-09-12 16:58:24 subjects: - ipej succeeds: ~ suggestions: ~ sword_depositor: ~ sword_slug: ~ thesistype: ~ title: "The implantable loop recorder: A tool that is \"here to stay\"\n" type: journalp userid: 4424 volume: 2