@prefix epid: .
@prefix dc: .
@prefix geo: .
@prefix bibo: .
@prefix epx: .
@prefix owl: .
@prefix void: .
@prefix event: .
@prefix skos: .
@prefix xsd: .
@prefix cc: .
@prefix ep: .
@prefix foaf: .
@prefix rdf: .
@prefix rdfs: .
@prefix eprel: .
@prefix dct: .
<>
foaf:primaryTopic ;
rdfs:comment "The repository administrator has not yet configured an RDF license."^^xsd:string .
rdfs:label "yash3.pdf"^^xsd:string .
rdfs:label "preview.png"^^xsd:string .
rdfs:label "indexcodes.txt"^^xsd:string .
dc:format "text/html";
dc:title "HTML Summary of #4178 \n\nIssues in QT interval measurement \n\n";
foaf:primaryTopic .
dct:hasPart ;
ep:hasFile ;
eprel:hasIndexCodesVersion ;
eprel:hasVersion ,
;
eprel:hasVolatileVersion ,
;
eprel:haspreviewThumbnailVersion ;
rdf:type bibo:Document,
ep:Document;
rdfs:label "Issues in QT interval measurement (PDF)"^^xsd:string .
dct:hasPart ;
ep:hasFile ;
eprel:isVersionOf ;
eprel:isVolatileVersionOf ;
eprel:ispreviewThumbnailVersionOf ;
rdf:type ep:Document;
rdfs:label "Issues in QT interval measurement (Image (PNG))"^^xsd:string .
dct:hasPart ;
ep:hasFile ;
eprel:isIndexCodesVersionOf ;
eprel:isVersionOf ;
eprel:isVolatileVersionOf ;
rdf:type ep:Document;
rdfs:label "Issues in QT interval measurement (Indexer Terms)"^^xsd:string .
rdf:_1 ;
rdf:_2 ;
rdf:_3 .
rdf:_1 ;
rdf:_2 ;
rdf:_3 ;
rdf:_4 .
,
,
,
;
bibo:abstract "The QT interval, apart from clinical implications is crucial for safety assessment of new drugs under development. A QTc prolongation of even 10 msec in a study group is a warning signal for a new drug. \n There are various issues involved in the measurement of the QT interval especially regarding the ending of the T wave and different morphological pattern of T-U complex. The other issue is significant spontaneous variability in the QT interval, resulting in spurious QT prolongation and unnecessary concern.\n To minimize all these confounding factors, all clinical trials for assessing QT interval prolongation should be randomized and double blinded with appropriate control groups including placebo. ECG measurements should be done by trained readers with electronic calipers at ECG core Lab. ECGs should be compared with multiple baseline values with multiple, time-matched on-treatment values.\n"^^xsd:string;
bibo:authorList ;
bibo:editorList ;
bibo:issue "4";
bibo:status ,
;
bibo:volume "4";
dct:creator ,
,
;
dct:date "2004-10";
dct:isPartOf ,
;
dct:publisher ;
dct:subject ;
dct:title "Issues in QT interval measurement "^^xsd:string;
ep:hasDocument ,
,
;
rdf:type bibo:Article,
ep:EPrint,
ep:JournalpEPrint;
rdfs:seeAlso .
rdf:type skos:Concept;
skos:prefLabel "Indian Pacing and Electrophysiology Journal" .
foaf:name "Indian Pacing and Electrophysiology Group"^^xsd:string;
rdf:type foaf:Organization .
foaf:familyName "Lanjewar"^^xsd:string;
foaf:givenName "Pallavi"^^xsd:string;
foaf:name "Pallavi Lanjewar"^^xsd:string;
rdf:type foaf:Person .
foaf:familyName "Francis"^^xsd:string;
foaf:givenName "Johnson"^^xsd:string;
foaf:name "Johnson Francis"^^xsd:string;
rdf:type foaf:Person .
foaf:familyName "Gupta"^^xsd:string;
foaf:givenName "Anup"^^xsd:string;
foaf:name "Anup Gupta"^^xsd:string;
rdf:type foaf:Person .
foaf:familyName "Singh"^^xsd:string;
foaf:givenName "Balbir"^^xsd:string;
foaf:name "Balbir Singh"^^xsd:string;
rdf:type foaf:Person .
foaf:familyName "Lokhandwala"^^xsd:string;
foaf:givenName "Yash"^^xsd:string;
foaf:name "Yash Lokhandwala"^^xsd:string;
rdf:type foaf:Person .
foaf:familyName "Pathak"^^xsd:string;
foaf:givenName "Vaishali"^^xsd:string;
foaf:name "Vaishali Pathak"^^xsd:string;
rdf:type foaf:Person .
foaf:name "Indian Pacing and Electrophysiology Journal"^^xsd:string;
rdf:type bibo:Collection .