John, Roy M (2004) Arrhythmia Diagnosis Following An ICD Shock. [Journal (Paginated)]
Full text available as:
| PDF 139Kb | |
| HTML 22Kb |
Abstract
A 70 year old male underwent placement of a Medtronic Marquis DR ICD following syncope. He has coronary artery disease and severe LV dysfunction and was inducible for rapid hemodynamically unstable ventricular tachycardia at intracardiac electrophysiological study prior to implantation of the ICD. Three weeks later, he presents with an ICD shock. He had been drinking excessive amounts of alcohol and experienced lightheadedness prior to experiencing the ICD shock. A ventricular arrhythmia is appropriately converted by the ICD shock
| Item Type: | Journal (Paginated) |
|---|---|
| Keywords: | Arrhythmia quiz |
| Subjects: | JOURNALS > Indian Pacing and Electrophysiology Journal |
| ID Code: | 4189 |
| Deposited By: | Indian Pacing and Electrophysiology, Journal |
| Deposited On: | 13 Apr 2005 |
| Last Modified: | 12 Sep 2007 17:56 |